Search results for "Radionuclide ventriculography"

showing 2 items of 2 documents

Left ventricular ejection fraction calculation from automatically selected and processed diastolic and systolic frames in short-axis cine-MRI

2005

International audience; Abstract: The calculation of the left ventricular ejection fraction (LVEF) is dependent upon the accurate measurement of diastolic and systolic left ventricular volumes. Although breath-hold cine magnetic resonance imaging (MRI) allows coverage of the whole cardiac cycle with an excellent time resolution, many authors rely on the visual selection of diastolic and the systolic short-axis slices in order to reduce the postprocessing time. An automatic method was developed to detect the endocardial contour on each image, allowing an automatic selection of the systolic frame. The calculated ejection fraction was compared with radionuclide ventriculography (RNV). Sixty-fi…

AdultMalemedicine.medical_specialtyShort axisHeart diseaseSystoleHeart VentriclesDiastoleMyocardial InfarctionMagnetic Resonance Imaging CineImage processingRadionuclide ventriculography030204 cardiovascular system & hematologyVentricular Function Left030218 nuclear medicine & medical imaging03 medical and health sciencesElectrocardiography0302 clinical medicineDiastoleInternal medicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingmedicineHumansmagnetic resonance imagingRadiology Nuclear Medicine and imagingRadionuclide VentriculographyAgedObserver VariationEjection fractionRadiological and Ultrasound Technologymedicine.diagnostic_testCardiac cycle[ INFO.INFO-IM ] Computer Science [cs]/Medical Imagingbusiness.industryMagnetic resonance imagingStroke Volumeleft ventricular ejection fractionMiddle Agedmedicine.diseaseimage processingCardiologyFemaleEndothelium Vascularfuzzy logicCardiology and Cardiovascular MedicinebusinessNuclear medicine
researchProduct

Analysis of left ventricular volumes and function: a multicenter comparison of cardiac magnetic resonance imaging, cine ventriculography, and unenhan…

2013

Background: Contrast echocardiography improves accuracy and reduces interreader variability on left ventricular (LV)functional analyses inthe settingof two-dimensional (2D) echocardiography. Theneedfor contrast imaging using three-dimensional (3D) echocardiography is less defined. The aim of this multicenter study was to define the accuracy and interreader agreement of unenhanced and contrast-enhanced 2D and 3D echocardiography for the assessment of LV volumes and ejection fraction (EF). Methods: A multicenter, open-label study was conducted including 63 patients, using intrasubject comparisons to assess the agreement of unenhanced and contrast-enhanced 2D and 3D echocardiography as well as…

Malemedicine.medical_specialtymedia_common.quotation_subjectEchocardiography Three-DimensionalSulfur HexafluorideContrast MediaMagnetic Resonance Imaging CineSensitivity and SpecificityVentricular Dysfunction LeftCardiac magnetic resonance imagingInternal medicinemedicineContrast (vision)HumansRadiology Nuclear Medicine and imagingSingle-Blind MethodRadionuclide VentriculographyPhospholipidsmedia_commonObserver VariationEjection fractionmedicine.diagnostic_testbusiness.industryReproducibility of ResultsThree dimensional echocardiographyStroke VolumeOrgan SizeConfidence intervalEuropeContrast echocardiographyCardiologyFemaleCardiology and Cardiovascular MedicinebusinessCardiac magnetic resonanceNuclear medicine3d echocardiographyJournal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
researchProduct